floor heating & cooling systems pipes controls
 
  about us
  projects
  news
  brochures
  education
  faq
  enquiries
  contact
  home
   
  home» systems » velta tecto 2 system
 
VELTA TECTO 2 SYSTEM
floor constructions
installation instructions
projects
specifications
 
velta tecto 2 system
For use with pumped flowing screed applications
 

The velta tecto 2 system has been designed to provide an excellent solution in modern construction where low profile floors and fast flowing screeds are used.

The velta tecto 2 system can be used on most commercial and domestic applications, including;

Houses
Flats
Schools
Health centres
Offices and administrative buildings

 

The velta tecto 2 fixing panels are the secret to the system providing a fully sealed floor area to contain the flowing screed together with other benefits:

Quick one man installation with the 1450mm x 850mm insulated velta tecto 2 panels
Insulated profile of the panels reduces the volume of screed on the floor to provide a system with low thermal mass, producing better and faster heat transfer
velta tecto 2 panels join together by overlapping the nodules to provide a completely sealed system
velta tecto 2 ND11 panel can accommodate floor loads of up to 6T/m2 and can be used with other insulation boards on ground floor applications
velta tecto 2 ND30 panel is specifically designed to provide insulation and noise reduction (28db) for intermediate floor applications
velta tecto 2 can utilise both 14 and 17mm velta PE-Xa pipe to suit the specific project
Correct and accurate pipe spacing on panels in increments of 50mm
Edge seals and door joints are designed into the system
Plastic cover profile to the board ensures that water from the screed does not contaminate the insulation and the screed cures correctly
The raised profile of the panel provides protection for the pipe during the installation

 


 
     
     
 

The correct preparation of the sub floor is important and velta planning instructions should be followed. Flowing screeds should be designed and installed in accordance with the manufacturer's instructions and BS 8024 Part 7.

All other screeds used should comply with the relevant sections of BS 8024.

 

Floor construction zones for floor insulation, velta tecto 2 and screed are typically 110mm for ground floor applications and 90mm on intermediate floors.

These can be reduced but our technical department must be consulted. 


  velta tecto 2 system is a complete solution for high speed modern floors
 
     
     
   
   
    top